1.Warning Light (Signal Light) DLF1-BN, OB, WN Series

Application

The OB low-intensity obstacle lights are
designed for aviation warning purpose.
They are suitable for installation on towers
or tall buildings in zone 1, 2 and zone
21, 22 hazardous areas.

TECHNICAL DATA
Hazardous Area Gas   Dust
Zones 1 & 2 21&22
Equipment Group/Category  Ex II 2G   Ex II 2D
Symbol of Protection  Ex db eb IIC T6/T5 Gb Ex  tb IIIC T80oC Db IP66
Certificate TÜV CY 18 ATEX 0206001 X 
Conformity to Standard EN 60079-0:2012+A11:2013, EN 60079-1:2014,
  EN 60079-7:2015, EN 60079-31:2014
Ambient Temperature -20oC to +55oC   
Index of Protection IP66  
     
Entries 2-M25x1.5 or 2-Ø3/4" NPT(1-Stopping plug)
Mounting  Ceiling or Bracket mouting(standard)
  (Optional mouting : 2x M10 eye bots, clamps for pipe)
Connection L, N and E ; for 1-4 mm.2  cable(Through wurung system with
  an extra terminal block for cable connection at both ends.
Rated Voltage 220/230/240V AC ±5% 50/60Hz
SPECIFICATION
Body material  : Marine grade copper-free aluminium alloy
    with polyester powder coated, RAL 7032 (grey)
Globe  : Broosilicate glass
Filter : Plastic (Watning Light)
Guard, bolts  : Stainless steel
Seal gasket : Silicone
Bracket : Hot-dip galvanized steel
OPTION
CATALOGUE NUMBER AND DIMENSION